Because of combined clopidogrel and aspirin resistance and to uns

Because of combined clopidogrel and aspirin resistance and to unsuccessful PCI treatment, a single coronary artery bypass graft (CABG) was planned. Awaiting surgery, 3 days later, the fourth ST occurred. It is angiographically confirmed and thus, CABG was

performed. After CABG, in R406 chronic treatment with aspirin (300 mg/die) and ticlopidine (500 mg/die), no bleeding complications occurred and the patient did not experience recurrent ischemia (2 years follow-up). A better platelet inhibition by ticlopidine than that obtained by clopidogrel was observed. Our case report remarks the importance to identify these poor responder patients as the treatment can be tailored with alternative therapeutic options (ticlopidine, prasugrel, warfarin) and/or different revascularization strategies (CABG).”
“Background: Near-infrared spectroscopy estimates soft-tissue oxygenation approximately 2 to 3 cm below the skin. The purpose of the present study was to evaluate muscle oxygenation in the setting of an acute compartment syndrome of the leg and to determine if near-infrared spectroscopy THZ1 manufacturer is capable of detecting perfusion deficits.\n\nMethods: Fourteen patients with unilateral lower extremity trauma

were enrolled after the diagnosis of an acute compartment syndrome was made clinically and confirmed with intracompartmental pressure measurements. Lower extremity muscle compartments were evaluated with near-infrared spectroscopy, and near-infrared spectroscopy values of the uninjured, contralateral leg of each patient were used as Galardin internal reference values. The compartment perfusion gradient was calculated as the diastolic blood pressure minus the intracompartmental pressure.\n\nResults: Intracompartmental pressures ranged from 21 to 176 mm Hg (mean, 79 mm Hg) and exceeded 30 mm Hg in all compartments but two (both in the same patient). Thirty-eight compartments had a perfusion gradient of 510 mm Hg (indicating ischemia). Among ischemic compartments, near-infrared

spectroscopy values in the anterior, lateral, deep posterior, and superficial posterior compartments of the injured limbs were decreased by an average 10.1%, 10.1%, 9.4%, and 16.3% in comparison with the corresponding compartments of the 4 uninjured leg. Differences in near-infrared spectroscopy values (the near-infrared spectroscopy value for the injured leg minus the near-infrared spectroscopy value for the uninjured leg) were positively correlated with compartment perfusion gradient within each compartment (r = 0.82, 0.65, 0.67, and 0.62, for the anterior, lateral, deep posterior, and superficial posterior compartments, respectively; p < 0.05 for all).\n\nConclusions: Normalized near-infrared spectroscopy values decrease significantly with decreasing lower limb perfusion pressures. Near-infrared spectroscopy may be capable of differentiating between injured patients with and without an acute compartment syndrome.

Comments are closed.